Table 38. Troubleshooting pH issues
Operational monitoring |
Parameter | Target criteria | Critical limits | Monitoring method |
pH | 6.5–7.8 | pH is adjusted as required to achieve optimal pH for the disinfectant used. | Online, continuous pH meter.
24-hour monitored alarms on monitoring meters.
Appropriate electronic or hard copy monitoring records. |
Corrective action
Any breach in critical limits or target criteria should result in any of the following operating procedures as necessary:
inspect and calibrate equipment,check the concentration of the chemical (if chemicals have expired),adjust flow rate,change to a different filter micron,change filtration point,carry out additional monitoring, increase sampling and testing,implement unplanned maintenance procedure,add a secondary filter,use alternative supply with low organic matter,engage backup equipment,plant automatic shutdown,implement emergency response, andrecord actions to be taken and report (internally or externally as required). |
Verification
Calibration and maintenance of equipmentpH monitoringSatisfactory productionEvaluation and audit |